Store the barrier fluid and maintain a pressure differential between the barrier fluid and the medium. The medium pressurizes the isolation fluid through a piston. The isolation fluid is pressurized according to the fixed transmission ratio of the pressurized tank. The maximum working pressure in the pressurized tank is 6.5Mpa.
The welding of all pressure-bearing parts is performed in accordance with JB / T4709-92. Use butt welding or double-sided butt welding.
增压罐图号 | 型号 | 压力 (MPa) | 设计温度 (℃) | 容积 | 增压比 | 材料 |
CYTBZ-ZYXT1 | HS-04-6.3-T-HG/T2122 | 6.3 | -20~100 | 4L | 1:1.1 | 20 |
CYTBZ-ZYXT2 | HS-04-6.3-B-HG/T2122 | 6.3 | -20~100 | 4L | 1:1.1 | 0Cr18Ni9 |
CYTBZ-ZYX3 | DLE5-15 | 4.0 | 150 | 16Mn |